Rockwell Automation 2098-UWCPRG Ultraware Software User Manual User Manual

Page 240

Advertising
background image

242

Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

Chapter 5 Configuring the Kinetix 3 Drive

Click Revert to return parameter settings to the values they held when you
opened this window.

1st Gear Ratio

Specifies the 1st ratio of counts between the master input
counts and the motor encoder counts (for example 1:4).
The range of the ratio value is 1:1… 1:6,553,5:65,535.

2nd Gear Ratio

Specifies the 1st ratio of counts between the master input
counts and the motor encoder counts (for example 1:4).
The range of the ratio value is from 1:1…1:6,553,5:65,535.

Digital Filter Cut-off Frequency The cutoff frequency of the low pass digital filter applied to the

pulse command input.
Line Driver Input:

The range is 0.525, 0.562, 0.625, 0.750, 1.000, 1.500, 1,750,
and 3.000 MHz. Default is 1.750 MHz

Open Collector Input:

The range is 0.525, 0.562, 0.625, 0.750, 1.000, 1.500, 1,750,
and 3.000 MHz. Default is 0.625 MHz

High Frequency Line Driver Input:

The range is 0.525, 0.562, 0.625, 0.750, 1.000, 1.500, 1,750,
and 3.000 MHz. Default is 3.000 MHz

Command

Description

Save Parameters

Saves the current working values as power-up values in flash
memory for the selected On-Line drive and all of its children.

Parameter

Description