Rockwell Automation Publication 2098-UM001G-EN-P - February 2011

193

Configuring the Ultra5000 Drive Chapter 4

Understanding Ultra5000
with DeviceNet

The Properties window for DeviceNet looks like this.

Use the DeviceNet window to:

configure a Ultra5000 drive with the Node Address = PGM, and

define message formats to transmit and receive.

The DeviceNet window has these parameters and statuses.

Parameter Description

Node Address

Node address used for DeviceNet communication. This value is
only used if the rotary switch on the front panel is configured for
PGM.

Data Rate

Data rate used for DeviceNet communication. This value is only
used if the rotary switch on the front panel is configured for
PGM. The options are:
125 kps
250 kps
500 kps
Autobaud

I/O Receive Select

Selects the output (consumed) assembly that is updated when a
polled, change of state, or cyclic I/O message is received by the
drive. The options are:
No Data Consumed
Assembly Instance 1
Assembly Instance 2
Assembly Instance 3
Assembly Instance 4
Assembly Instance 5
Assembly Instance 6
Assembly Instance 7
Assembly Instance 8
Note: Refer to the

Ultra5000 IPD with DeviceNet Reference

Manual, publication 2098-RM002

(

Ultra5000 IPD with

DeviceNet Reference Manual, publication 2098-RM002

) for

information on these options.