Parameter Descriptions

11-5

The output frequency present at T1, T2, and T3 (U, V, and W). This
value includes reference, slip comp, and IR compensation.

The value of the active pre-ramp reference frequency command.

The total output current present at T1, T2, and T3 (U, V, and W),
which includes torque and flux components.

The amount of current that is in phase with the fundamental voltage
component. This is the torque-producing component of the output
current.

1

Output Freq

Range:

+/-400.0 Hz [0.1 Hz]

Default:

Read Only

Access:

0

Path: Monitor>Metering

See also:

2

Commanded Freq

Range:

+/- 400.0 Hz [0.1 Hz]

Default:

Read Only

Access:

0

Path: Monitor>Metering

See also:

3

Output Current

Range:

0.0 to Drive Rated Amps x 2 [0.1 Amps]

Default:

Read Only

Access:

0

Path: Monitor>Metering

See also:

4

Torque Current

Range:

Drive Rating x -2 to +2 [0.1 Amps]

Default:

Read Only

Access:

1

Path: Monitor>Metering

See also: