Parameter Descriptions
11-57
Displays which User Set was last loaded into active memory. User
parameter changes are allowed after a User Set is restored, but will
not be detected or annunciated.
Present operating status of the drive.
Figure 11.17 – DynUsrSetSel
206
Dyn UserSet Actv
Range:
0 = Normal Mode (Dynamic Mode Disabled)
1 = User Set 1
2 = User Set 2
3 = User Set 3
Default:
Read Only
Access:
2
Path: Utility>Drive Memory
See also:
204, 205
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Enabled
0 =Disabled
x =Reserved
Bit #
Factory Default Bit Values
UserSetBit0
UserSetBit1
Nibble 1
Nibble 2
Nibble 3
Nibble 4
209
Drive Status 1
Range:
See figure11.18
Default:
Read Only
Access:
2
Path: Utility>Diagnostics