Rockwell Automation SP600 User Manual Version 3.0 User Manual
Page 126

11-24
SP600 AC Drive User Manual
Scales the upper value of the Speed Ref Sel (90) selection when
the source is an analog input. This value corresponds to the value
entered in parameter 322 or 324.
Scales the lower value of the Speed Ref A Sel (90) selection when
the source is an analog input. This value corresponds to the value
entered in parameter 323 or 325.
Specifies the manual speed reference source when a digital input is
configured for manual selection. See parameters 361 to 366.
Scales the upper value of the TB Man Ref Sel selection when the
source is an analog input. This parameter should be set in
conjunction with parameter 322 or 325, depending on the analog
input being used.
91
Speed Ref A Hi
Range:
-/+ Maximum Speed [0.1 Hz]
Default:
Maximum Speed
Access:
1
Path: Speed Command>Speed References
See also:
82, 322, 324
92
Speed Ref A Lo
Range:
-/+ Maximum Speed [0.1 Hz]
Default:
0.0 Hz
Access:
1
Path: Speed Command>Speed References
See also:
81, 323, 325
96
TB Man Ref Sel
Range:
1 = Analog In 1
2 = Analog In 2
3-8 = Reserved
9 = MOP Level
Default:
2 = Analog In 2
Access:
1
Path: Speed Command>Speed References
See also:
97, 98
97
TB Man Ref Hi
Range:
-/+Maximum Speed [0.1 Hz]
Default:
Maximum Speed
Access:
1
Path: Speed Command>Speed References
See also:
96, 322, 324