Rockwell Automation SP600 User Manual Version 3.0 User Manual
Page 156
Advertising
11-54
SP600 AC Drive User Manual
Saves the parameter values in active drive memory to a user set in
drive non-volatile memory.
An F-Key on the LCD OIM can be configured for this function. Refer
to Appendix B.
Resets selected meters to zero.
Selects the display language when using an LCD OIM.
199
Save To User Set
Range:
0 = Ready
1 = User Set 1
2 = User Set 2
3 = User Set 3
Default:
0 = Ready
Access:
1
Path: Utility>Drive Memory
See also:
198
200
Reset Meters
Range:
0 = Ready
1 = MWh
2 = Elapsed Time
Default:
0 = Ready
Access:
1
Path: Utility>Drive Memory
See also:
201
Language
Range:
0 = Not Selected
1 = English
2 = French
3 = Spanish
4 = Italian
5 = German
6 = Reserved
7 = Portuguese
Default:
0 = Not Selected
Access:
2
Path: Utility>Drive Memory
See also:
Advertising