1 = DynUsrSetSel: DynUsrSetSel (205) determines the active User
Set.

Controls which User Set is in memory when Ctrl Source (bit 1) of
DynUsrSetCnfg (204) is set to DynUsrSetSel.

Bit 0 - UserSetBit0

0 = Disabled

1 = Enabled

Bit 1 -UserSetBit1

0 = Disabled

1 =Enabled

Figure 11.16 – Dyn UserSet Cnfg

205

DynUsrSetSel

Range:

See figure 11.17.

Default:

See figure 11.17.

Access:

2

Path: Utility>Drive Memory

See also:

204, 206

0

x

x

0

x

x

x

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

Bit 0:
1
=Enabled
0 =Disabled

Bit 1:
1 = DynUsrSetSel
0 = Digital Inputs

x = Reserved

Bit #

Factory Default Bit Values

Dynamic Mode

Ctr

l Source

Nibble 1

Nibble 2

Nibble 3

Nibble 4

Table 11.4 – Dynamic User Set Mode

UserSetBit1

UserSetBit0

UserSet Loaded in Memory

0

0

User Set 1

0

1

User Set 2

1

0

User Set 3

1

1

User Set 3