Rockwell Automation SP600 User Manual Version 3.0 User Manual
Page 182
11-80
SP600 AC Drive User Manual
Selects the mode for the analog output.
Selects whether the signed value or absolute value of a parameter
is used before being scaled to drive the analog output.
340
Anlg Out Config
Range:
See figure 11.37
Default:
0
Access:
1
Path: Inputs & Outputs>Analog Outputs
See also:
Figure 11.37 – Analog Out Config
x
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Current
0 =Voltage
x =Reserved
Bit #
Factory Default Bit Values
Analog Out1
341
Anlg Out Absolut
Range:
See figure 11.38
Default:
See figure 11.38
Access:
2
Path: Inputs & Outputs>Analog Outputs
See also:
342
Figure 11.38 – Anlg Out Absolute (341)
x
x
x
1
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Absolute
0 =Signed
x =Reserved
Bit #
Factory Default Bit Values
Analog Out1
Bit
Signal Level
Output Volts
0
-100%
0%
100%
0 V
5 V
10 V
1
-100%
0%
100%
10 V
0 V
10 V