2-6

SP600 AC Drive User Manual

2.3.5 Multiple Stop Methods

There are several stop methods that can be selected using drive
parameters 155 and 156:

Coast to Stop

Brake to Stop

Ramp to Stop

Ramp to Hold

Refer to the parameter descriptions in chapter 11 for more
information about these stop mode selections.

Another stop method, dynamic braking, uses an optional internal or
external DB braking resistor to dissipate stopping energy. See
parameters 161 to 163 for more information about this feature.

2.3.6 Multiple Speed Control Methods

The purpose of speed regulation is to allow the drive to adjust to
certain operating conditions, such as load change, and compensate
for these changes in an attempt to maintain motor shaft speed
within the specified regulation percentage.

The Speed Mode parameter (80) selects the speed regulation
method for the drive, and can be set to one of 3 choices

Open Loop - No speed control is offered

Slip Comp - Slip Compensation is active

Process PI - The PI loop sets the actual speed based on process
variables.

Refer to parameter 80 in chapter 11 for more information.

2.3.7 Auto/Manual Reference Selection

You can override the selected “auto” reference by either toggling a
function key on the OIM or asserting a digital input (Digital In”x” Sel
(361 to 366)) that has been configured for Manual. This provides a
source for local speed reference control even if a process input
signal is the primary speed reference source.

Refer to the parameter descriptions in chapter 11 for more
information.