Parameter Descriptions

11-69

Elapsed hours since drive power up. This value will rollover to 0
after the drive has been powered on for more than the maximum
value shown.

Selects conditions that will initiate a drive alarm.

Refer to chapter 12, Troubleshooting the Drive, for alarm definitions.

242

Power Up Marker

Range:

0.0000 to 4,294,967.2925 Hr [0.0001 Hr]

Default:

Read Only

Access:

2

Path: Utility>Faults

See also:

244, 246, 248, 250

32

259

Alarm Config 1

Range:

See figure 11.30

Default:

See figure 11.30

Access:

2

Path: Utility>Alarms

See also:

Figure 11.30 – Alarm Config 1 (259)

1

1

x

1

1

1

x

1

1

1

1

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Enabled
0 =Disabled
x =Reserved

Bit #

Factory Default Bit Values

Prechrg Actv

UnderV

oltage

Po

w

er Loss

Anlg in Loss

IntDBRes OH

Dr

v OL Lvl 1

Dr

v OL Lvl 2

Decel inhibit

W

aking

Nibble 1

Nibble 2

Nibble 3

Nibble 4