Rockwell Automation SP600 User Manual Version 3.0 User Manual

Page 230

Advertising
background image

A-6

SP600 AC Drive User Manual

Selectable Motor Control

Sensorless Vector with full tuning. Standard
V/Hz with full custom capability.

Stop Modes

Multiple programmable stop modes including
Ramp, Coast, DC-Brake, Ramp-to-Hold and
S-curve.

Accel/Decel

Two independently programmable accel and
decel times. Each time may be programmed
from 0 - 3600 seconds in 0.1 second
increments.

Table A.5 – Control Specifications

Table A.6 – Analog Interface Specifications

Analog Input 1,
Differential Voltage Input
Signal level
Differential Input resistance
Isolation
Resolution
Input processing period

-10V to +10V
100k

Ω

160V
11 bits plus sign
5ms

Analog Input 1,
Differential Current Input
Signal level
Differential Input resistance
Resolution
Input processing period

0(4) to 20mA
124

Ω

11 bits plus sign
5ms

Analog Input 2,
Differential Voltage Input
Signal level
Differential Input resistance
Initial accuracy (@25°C)
Resolution
Input processing period

-10V to +10V
100k

Ω

160V
11 bits plus sign
5ms

Analog Input 2,
Differential Current Input
Signal level
Differential Input resistance
Resolution
Input processing period

0(4) to 20mA
124

Ω

11 bits plus sign
5ms