Rockwell Automation SP600 User Manual Version 3.0 User Manual

Page 110

Advertising
background image

11-8

SP600 AC Drive User Manual

The value of the signal at the analog inputs. This value does not
include scaling information programmed by the user (for example,
Analog In1 Hi). The terminals monitored depend on the setting of
Anlg In Config (320). The inputs can be configured as voltage or
current.

The drive power rating.

The drive input voltage class (208, 240, 400, etc.).

The drive rated output current.

16
17

Analog In1 Value
Analog In2 Value

Range:

4.000 to 20.000 mA [0.001 mA]
-/+10.0 V [0.1 V]

Default:

Read Only

Access:

16=1
17=1

Path: Monitor>Metering

See also:

320

26

Rated kW

Range:

0.37 to 87.0 kW [0.1 kW]

Default:

Read Only

Access:

0

Path: Monitor>Drive Data

See also:

32

27

Rated Volts

Range:

208 to 600 V [0.1 VAC]

Default:

Read Only

Access:

0

Path: Monitor>Drive Data

See also:

28

Rated Amps

Range:

1.1 to 125.0 Amps [0.1 Amps]

Default:

Read Only

Access:

0

Path: Monitor>Drive Data

See also: