Rockwell Automation SP600 User Manual Version 3.0 User Manual
Page 110
![background image](/manuals/580884/110/background.png)
11-8
SP600 AC Drive User Manual
The value of the signal at the analog inputs. This value does not
include scaling information programmed by the user (for example,
Analog In1 Hi). The terminals monitored depend on the setting of
Anlg In Config (320). The inputs can be configured as voltage or
current.
The drive power rating.
The drive input voltage class (208, 240, 400, etc.).
The drive rated output current.
16
17
Analog In1 Value
Analog In2 Value
Range:
4.000 to 20.000 mA [0.001 mA]
-/+10.0 V [0.1 V]
Default:
Read Only
Access:
16=1
17=1
Path: Monitor>Metering
See also:
320
26
Rated kW
Range:
0.37 to 87.0 kW [0.1 kW]
Default:
Read Only
Access:
0
Path: Monitor>Drive Data
See also:
32
27
Rated Volts
Range:
208 to 600 V [0.1 VAC]
Default:
Read Only
Access:
0
Path: Monitor>Drive Data
See also:
28
Rated Amps
Range:
1.1 to 125.0 Amps [0.1 Amps]
Default:
Read Only
Access:
0
Path: Monitor>Drive Data
See also: