Speed Ref A Sel (90) or PI Reference Sel (126) is set to
Reserved.
Under-
Voltage
The bus voltage has dropped below a predetermined
value.
User Set
Conflict
Digital Inputs on Dynamic User Sets do not match.
Datalinks on Dynamic User Sets do not match.
VHz Neg
Slope
Custom V/Hz mode has been selected in Torq Perf Mode
(53) and the V/Hz slope is negative.
Waking
The wake timer is counting toward a value that will start
the drive.
Table 12.4 – Alarm Descriptions (Continued)
Alarm
Ty
p
e
Description
Table 12.5 – Alarm Names Cross-Referenced by Alarm Numbers
No.
1
1
Alarm numbers not listed are reserved for future use.
Alarm
No.
1
Alarm
1
Precharge Active
20
Bipolar Conflict
2
UnderVoltage
21
Motor Type Conflict
3
Power Loss
22
NP Hz Conflict
5
Analog In Loss
23
MaxFreq Conflict
6
IntDBRes OvrHeat
24
VHz Neg Slope
8
Drive OL Level 1
25
IR Volts Range
9
Drive OL Level 2
26
FluxAmps Ref Rang
10
Decel Inhibit
27
Speed Ref Cflct
11
Waking
28
Ixo Vlt Rang
17
Dig In ConflictA
29
Sleep Config
18
Dig In ConflictB
30
DigIn Bad Value
19
Dig In ConflictC
32
User Set Conflict