B-12, B.8.3.1 customizing the function key label text – Rockwell Automation SP600 User Manual Version 3.0 User Manual

Page 244

Advertising
background image

B-12

SP600 AC Drive User Manual

Auto/Manual: Toggles between Auto and Manual reference control.
The text above the function key will change to indicate the
command that will be issued when the key is pressed.

View Fault Queue: Displays the Fault Queue screen (see chapter
12). Press

to return to the process display screen.

Next: Toggles to next set of three process display variables.

B.8.3.1 Customizing the Function Key Label Text

You can customize the text for each function key label (up to five
characters). See figure B.10.

!

ATTENTION: When switching from Auto to Manual
or Manual to Auto, the drive will ramp to the reference
level provided by the new source at the rate specified
in Accel Time 1 (140), Decel Time 1 (142), Accel
Time 2 (141), or Decel Time 2 (143). Be aware that
an abrupt speed change may occur depending upon
the new reference level and rate specified in these
parameters. Failure to observe this precaution could
result in bodily injury.

ESC/
PROG

Figure B.10 – Customizing the Function Key Label Text

Function List:

Load User Set 1

Load User Set 2

Undefined

Do You Wish to
Rename Function

States Text For:

Load User Set 1

Yes

No

Function List

F2: Undefined
F3: Undefined

F1: Load User Set 1

ClrFK

Name State Text:

FKey Text

Luse

A

A

BCDEFGHIJKLM

Next

F1

F2

OIM will use default

F-Key label Luse1

Function List

F2: Undefined
F3: Undefined

F1: Load User Set 1

ClrFK

F4

OIM will use custom

F-Key label LuseA

Move through label text

Move through letters and
symbols

P0: SP600

Auto

Stopped

Fltq

0.00

Volts

Amps

Hz

0.00

0.00

Luse1

P0: SP600

Auto

Stopped

Fltq

0.00

Volts

Amps

Hz

0.00
0.00

LuseA

A->a Save

F3

Esc or timeout to
Process Display
screen

Esc or timeout to
Process Display
screen

From figure

B.9

Toggle between upper

and lower case

>>

>>

Advertising