299 dpi fdbk select – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual
Page 106

3-80
DBT Reach Drive User Manual
Selects the data to be copied into the DPI feedback data register.
Parameter number whose value will be written from a communications device data
table.
Standard Control = Parameters that can be changed only while the drive is stopped
cannot be used as Datalink inputs. Entering a parameter of this type will disable the
link
Vector Control = Will not be updated until drive is stopped.
Refer to the appropriate communications option board manual for datalink information.
299
DPI Fdbk Select
Range:
0 = Output Freq
1 = Command Spd
2 = Output Amps
3 = Torque Amps
4 = Flux Amps
5 = Output Power
6 = Output Volts
7 = DC Bus Volts
8 = PI Reference
9 = PI Feedback
10 = PI Error
11 = PI Output
12 = %Motor OL
13 = %Drive OL
14 = CommandedTrq
15 = MtrTrqCurRef
16 = Speed Ref
17 = Speed Fdbk
18 = Pulse ln Ref
19 = Reserved
20 = Scale Block 1
21 = Scale Block 2
22 = Scale Block 3
23 = Scale Block 4
24 = Param Cntl
25 = SpdFb NoFilt
Default:
17 = Speed Fdbk
Access:
2
Path: Communication>Comm Control
See also:
300
301
Data In A1 - Link A Word 1
Data In A2 - Link A Word 2
Range:
0 to 611 [1]
Default:
0 (Disabled)
Access:
2
Path: Communication>Datalinks