416 fdbk filter sel, 419 notch filter freq, 420 notch filter k – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 132: 421 marker pulse

Advertising
background image

3-106

DBT Reach Drive User Manual

Selects the type of feedback filter desired. “Light” uses a 35/49 radian feedback filter.
“Heavy” uses a 20/40 radian feedback filter.

Sets the center frequency for an optional 2-pole notch filter. Filter is applied to the
torque command. 0 disables this filter.

Sets the gain for the 2-pole notch filter.

Latches the raw encoder count at each marker pulse.

416

Fdbk Filter Sel

Range:

0 = None
1 = Light
2 = Heavy

Default:

0 = None

Access:

1

Path: Motor Control>Speed Feedback

See also:

419

Notch Filter Freq

Range:

0.0 to 500.0 Hz [0.1 Hz]

Default:

Read Only

Access:

1

Path: Motor Control>Speed Feedback

See also:

53

FV

420

Notch Filter K

Range:

0.1 to 0.9 Hz [0.1 Hz]

Default:

0.3 Hz

Access:

1

Path: Motor Control>Speed Feedback

See also:

53

FV

421

Marker Pulse

Range:

-/+ 2147483647 [1]

Default:

Read Only

Access:

1

Path: Motor Control>Speed Feedback

See also:

FV

Advertising