Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 198

Advertising
background image

A-2

DBT Reach Drive User Manual

Table A.3 – Environment

Altitude

1000 m (3300 ft) max. without derating

Ambient Operating
Temperature without
derating:
IP20, NEMA 1

–10 to 60

° C (14 to 140° F)

Storage Temperature (all
const.)

–40 to 70

° C (–40 to 158° F)

Atmosphere

Important: Drive must not be installed in an area
where the ambient temperature contains volatile or
corrosive gas, vapors, or dust. If the drive is not going
to be installed for a period of time, it must be stored in
an area where it will not be exposed to a corrosive
atmosphere.

Relative Humidity

5 to 95% non-condensing

Shock

40G peak for 6ms duration (

±3.0 ms)

Vibration

Sinusoidal:
0.35mm constant displacement to a constant
acceleration of 5G.
10-500 Hz
1 octave/min
10 sweep cycles
3 axis

Random:
0.05g

2

/Hz

10 Hz to 500 Hz
3 axes at 30 minutes/axis

Table A.4 – Input Specifications

Input Voltage

480 V RMS +10% -15%
(Operate to -50% with reduced power, -30% minimum
for precharge)
Note: The Reach Drive requires a 3% input impedance.

Input Frequency Range

47 to 63 Hz

Line to Neutral Phase
Imbalance Tolerance

2%

Table A.5 – Control Specifications

Method

Sine coded PWM with programmable carrier frequency.
Ratings apply to all drives. The drive can be supplied as
6-pulse or 12-pulse in a configured package.

Carrier Frequency

2-10 kHz. Drive rating based on 4 kHz

Output Voltage Range

0 to rated motor voltage

Output Frequency
Range

0 to 420 Hz.

Frequency Accuracy

Digital Input
Analog Input

Within

±0.01% of set output frequency

Within

±0.4% of maximum output frequency