3-119

Sets the rate to ramp the torque limits to zero during brake proving.

Sets the number of encoder counts to define a brake slippage condition.

Sets the number of motor shaft revolutions allowed during the brake slippage test.
Drive torque is reduced to check for brake slippage. When slippage occurs, the drive
allows this number of motor shaft revolutions before regaining control. Not used in
Encoderless Torque Prove mode.

Sets the percent of speed reference to be used when micropositioning has been
selected. Motor must come to a stop before this setting will take effect.

608

TorqLim SlewRate

Range:

0.5 to 300.0 sec [0.1 sec]

Default:

10.0 sec

Access:

2

Path: Applications>Torque Proving

See also:

609

BrkSlip Count

Range:

0 to 65535 [1]

Default:

250

Access:

2

Path: Applications>Torque Proving

See also:

610

Brk Alarm Travel

Range:

0.0 to 1000.0 Revs [0.1 Revs]

Default:

1.0 Revs

Access:

2

Path: Applications>Torque Proving

See also:

611

MicroPos Scale%

Range:

0.1 to 100.0% [0.1%]

Default:

10.0%

Access:

2

Path: Applications>Torque Proving

See also: