719 pos reg gain – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 158

Advertising
background image

3-132

DBT Reach Drive User Manual

Sets the gain adjustment for the position regulator.

Selects the type of move for a particular step.

The following steps use the velocity regulator only:

0 = End: Drive ramps to zero speed and stops the profile after the programmed dwell
time.

1 = Time: Drive ramps to step velocity, holds speed and decels to zero in specified
step value time.

719

Pos Reg Gain

Range:

0.0 to 200.0 [0.1]

Default:

4.0

Access:

2

Path: Pos/Spd Profile>ProfSetup/Status

See also:

720
730
740
750
760
770
780
790
800
810
820
830
840
850
860
870

Step 1 Type
Step 2 Type
Step 3 Type
Step 4 Type
Step 5 Type
Step 6 Type
Step 7 Type
Step 8 Type
Step 9 Type
Step 10 Type
Step 11 Type
Step 12 Type
Step 13 Type
Step 14 Type
Step 15 Type
Step 16 Type

Range:

0 = End
1 = Time
2 = Time Blend
3 = Dig Input
4 = Encoder Incr
5 = EnclncrBlend
6 = Enc Absolute
7 = End Hold Pos
8 = Param Level

Default:

1 = Time

Access:

2

Path: Pos/Spd Profile>Profile Step 1-16

See also: