Application Notes

Appendix D-23

Voltage Tolerance

Example:

Calculate the maximum power of a 5 HP, 460V motor connected to a 480V rated drive
supplied with 342V Actual Line Voltage input.

Actual Line Voltage / Nominal Motor Voltage = 74.3%

74.3%

× 60 Hz = 44.6 Hz

Table D.4 – Voltage Tolerance

Drive

Rating

Nominal

Line Voltage

Nominale

Motor Voltage

Drive Full

Power Range

Drive

Operating

Range

380-400

380

380*

380-528

342-528

400

400

400-528

460

460

528

Drive Full Power Range =

Nominal Motor Voltage to Drive Rated Voltage
+10%.
Rated power is available across the entire Drive Full
Power Range.

Drive Operating Range =

Lowest (*) Nominal Motor Voltage –10% to Drive
Rated Voltage +10%.
Drive Output is linearly derated when Actual Line
Voltage is less than the Nominal Motor Voltage.

HP @ Motor (Drive Output)

Actual Line Voltage (Drive Input)

Full Power Range

Drive Operating Range

Nominal Motor Voltage -10%

Nominal Motor Voltage

Derated Power Range

Drive Rated Voltage

Drive Rated Voltage +10%