612 torq prove sts, 631 rod load torque, 632 torqalarm level – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 146: 633 torqalarm action

Advertising
background image

3-120

DBT Reach Drive User Manual

Displays the status bits for Torque Proving.

Displays the load side torque.

Sets the level at which the Torque Alarm becomes active.

Sets the drive action when the Torque Alarm is exceeded.

612

Torq Prove Sts

Range:

See figure 3.41

Default:

Read Only

Access:

2

Path: Applications>Torque Proving

See also:

Figure 3.41 – Torq Prove Sts

0

0

0

x

0

0

0

0

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Enabled
0 =Disabled
x =Reserved

Bit #

EndLimitActv

DecelLimActv

Micr

oP

osActv

BrkSlipAlarm

Brake Set

LoadT

estActv

RefLoadLimtd

631

Rod Load Torque

Range:

0.00 to 32000.00 ft-lb [0.01 ft-lb]

Default:

Read Only

Access:

2

Path: Applications>Oil Well Pump

See also:

632

TorqAlarm Level

Range:

0.00 to 5000.00 ft-lb [0.01 ft-lb]

Default:

0.00 ft-lb

Access:

2

Path: Applications>Oil Well Pump

See also:

633

TorqAlarm Action

Range:

0 = No Action
1 = Goto Preset 1

Default:

0 = No Action

Access:

2

Path: Applications>Oil Well Pump

See also: