Parameter Descriptions

3-11

Enables/disables the compensation correction options.

Reflect Wave = Enables/disables reflected wave correction software, which reduces
overvoltage transients from the drive to the motor. For lead lengths beyond 300 feet,
enable this feature.

Figure 3.1 – Speed Limits

Frequency

Overspeed

Limit

(83)

Frequency Trim
due to Speed
Control Mode

Max Volts

(54)

Motor Volts

(41)

Run

Boost

(70)

Break Volts

(71)

Start Boost

(69)

Allowable Output Frequency Range - Normal Operation

Allowable Speed Reference Range

Allowable Output Frequency Range -

Bus Regulation or Current Limit

Maximum

Freq

(55)

Motor NP Hz

(43)

0

Break

Frequency

(72)

Max

Speed

(82)

Min

Speed

(81)

Output

Freq Limit

V
o

l
t

a
g
e

56

Compensation

Range:

See figure 3.2

Default:

See figure 3.2

Access:

2

Path: Motor Control>Torq Attributes

See also:

Figure 3.2 – Compensation (56)

1

0

1

1

1

0

x

0

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Enabled
0 =Disabled
x =Reserved

Bit #

Factory Default Bit Values

(1)

For current limit (except FVC Vector mode).

Reflect W

av

e

Enab

le Jerk

(1)

Ixo A

utoCalc

Xsistor Dia

g

Rs Adapt

Mtr Lead Re

v

PWM FreqLoc

k

TPEncdless

0