529 torque reg trim, 530 slip reg enable, 531 kp slip reg – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 173: 532 ki slip reg

Advertising
background image

Parameter Descriptions

3-147

Torque Regulator Trim gain. A larger value increases the developed torque. Typically
used to compensate for losses between developed and shaft torque.

Enables or disables the slip frequency regulator.

Proportional gain for the slip frequency regulator.

Integral gain for the slip frequency regulator.

529

Torque Reg Trim

Range:

0.5 to 1.5 [0.1]

Default:

1.00

Access:

2

Path: Utility>Diag-Vector Cnt

See also:

530

Slip Reg Enable

Range:

0 to 1 [1]

Default:

1

Access:

2

Path: Utility>Diag-Vector Cnt

See also:

531

Kp Slip Reg

Range:

0 to 32767 [1]

Default:

256

Access:

2

Path: Utility>Diag-Vector Cnt

See also:

532

Ki Slip Reg

Range:

0 to 32767 [1]

Default:

64

Access:

2

Path: Utility>Diag-Vector Cnt

See also: