4-6

DBT Reach Drive User Manual

TB Man
Ref Cflct

30

Occurs when:

“Auto/Manual” is selected (default) for Digital ln3 Sel (363) and

TB Man Ref Sel (96) has been reprogrammed.

No other use for the selected analog input may be programmed.
Example: If TB Man Ref Sel is reprogrammed to “Analog ln 2,” all of
the factory default uses for “Analog ln 2” must be reprogrammed.

To correct:

Verify/reprogram the parameters that reference an analog input or

Reprogram Digital ln3 to another function or “Unused.”

TorqProve

Cflct

49

When TorqProve Cnfg is enabled, Motor CntlSel, Feedback Select,
and Motor Fdbk Type must be properly set.

Under-
Voltage

2

The bus voltage has dropped below a predetermined value.

VHz Neg
Slope

24

Custom V/Hz mode has been selected in Torq Perf Mode (53) and
the V/Hz slope is negative.

Waking

11

The Wake timer is counting toward a value that will start the drive.

Table 4.3 – Alarm Names Cross-Referenced by Alarm Numbers

No.

1

1.Alarm numbers not listed are reserved for future use.

Alarm

No.

1

Alarm

No.

1

Alarm

1

Precharge Active

13

ln Phase Loss

25

IR Volts Range

2

UnderVoltage

14

Load Loss

26

FluxAmps Ref Rang

3

Power Loss

15

Ground Warn

27

Speed Ref Cflct

4

Start At PowerUp

17

Dig ln ConflictA

28

Ixo Vlt Rang

5

Analog In Loss

18

Dig ln ConflictB

29

Sleep Config

6

IntDBRes OvrHeat

19

Dig ln ConflictC

30

TB Man Ref Cflct

8

Drive OL Level 1

20

Bipolar Conflict

31

PTC Conflict

9

Drive OL Level 2

21

Motor Type Conflict

32

Brake Slipped

10

Decel Inhibit

22

NP Hz Conflict

34

Home Not Set

11

Waking

23

MaxFreq Conflict

49

Torq Prove Cflct

12

Motor Thermistor

24

VHz Neg Slope

50

Prof Step Cflct

Table 4.2 – Alarm Descriptions (Continued)

Alarm

No

.

Ty

p

e

Description