538 rec delay time, 539 ki freq reg, 540 kp freq reg – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 175: 541 encdlss ang comp

Advertising
background image

Parameter Descriptions

3-149

TBD

Integral gain for the Frequency Regulator.

Proportional gain for the Frequency Regulator.

Angle used to compensate for long cables attached to inverter and motor. Identified
during autotune for Encoderless FVC.

538

Rec Delay Time

Range:

1 to 30000 [1]

Default:

1000

Access:

2

Path: Utility>Diag-Motor Cntl

See also:

539

Ki Freq Reg

Range:

0 to 32767 [1]

Default:

450

Access:

2

Path: Utility>Diag-Vector Cnt

See also:

540

Kp Freq Reg

Range:

0 to 32767 [1]

Default:

2000

Access:

2

Path: Utility>Diag-Vector Cnt

See also:

541

Encdlss Ang Comp

Range:

-1023 to 1023 [1]

Default:

0

Access:

2

Path: Utility>Diag-Vector Cnt

See also: