392 dig out invert – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 128

Advertising
background image

3-102

DBT Reach Drive User Manual

Sets the off delay time for the digital outputs. This is the time between the
disappearance of a condition and de-activation of the relay.

Inverts the selected digital output.

383
387
391

Digital Out1 OffTime
Digital Out2 OffTime
Digital Out3 OffTime

Range:

0.00 to 600.00 sec [0.1 sec]

Default:

0.00 sec

Access:

2

Path: Inputs & Outputs>Digital Outputs

See also:

380

392

Dig Out Invert

Range:

See figure 3.36

Default:

See figure 3.36

Access:

2

Path: Inputs & Outputs>Digital Outputs

See also:

Figure 3.36 – Dig Out Invert

0

0

x

0

x

x

x

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Inverted
0 =Not Inverted
x =Reserved

Bit #

Factory Default Bit Values

Digital Out1

Digital Out2

Digital Out3