DBT Reach Drive User Manual

Sets the incremental amount of the output frequency (above Maximum Speed)
allowable for functions such as slip compensation. See figure 3.3.

Maximum Speed + Overspeed Limit must be

≤ to Maximum Frequency

!

ATTENTION: The user is responsible for ensuring that the driven
machinery, all drive-train mechanisms, and application material are
capable of safe operation at the maximum operating speed of the drive.
Overspeed detection in the drive determines when the drive shuts down.
The factory default for overspeed detection is set to 10.0 Hz (or 300.0
RPM) greater than the Maximum Speed (82). Failure to observe this
precaution could result in equipment damage, sever injury or loss of life.

83

Overspeed Limit

Range:

0.0 to 20.0 Hz [0.1 Hz] or 0.0 to 600.0 RPM [0.1 RPM]

Default:

10.0 Hz or 300.0 RPM

Access:

2

Path: Speed Command>Spd Mode & Limits

See also:

55, 79, 82

!

ATTENTION: The user is responsible for ensuring that the driven
machinery, all drive-train mechanisms, and application material are
capable of safe operation at the maximum operating speed of the drive.
Overspeed detection in the drive determines when the drive shuts down.
The factory default for overspeed detection is set to 10.0 Hz (or 300.0
RPM) greater than the Maximum Speed (82). Failure to observe this
precaution could result in equipment damage, sever injury or loss of life.

Figure 3.3 – Speed Limits

Frequency

Overspeed

Limit

(83)

Frequency Trim
due to Speed
Control Mode

Max Volts

(54)

Motor Volts

(41)

Run

Boost

(70)

Break Volts

(71)

Start Boost

(69)

Allowable Output Frequency Range - Normal Operation

Allowable Speed Reference Range

Allowable Output Frequency Range -

Bus Regulation or Current Limit

Maximum

Freq

(55)

Motor NP Hz

(43)

0

Break

Frequency

(72)

Max

Speed

(82)

Min

Speed

(81)

Output

Freq Limit

V
o

l
t

a
g
e

Advertising