C-8

DBT Reach Drive User Manual

Numeric Keypad Shortcut

If using a HIM with a numeric keypad, press the ALT key and the +/– key to access the
parameter by typing its number.

Linking Parameters (Vector Control Option Only)

Most parameter values are entered directly by the user. However, certain parameters
can be “linked,” so the value of one parameter becomes the value of another. For
Example: the value of an analog input can be linked to Accel Time 2 (141). Rather
than entering an acceleration time directly (via HIM), the link allows the value to
change by varying the analog signal. This can provide additional flexibility for
advanced applications.

Each link has 2 components:

Source parameter – sender of information.

Destination parameter – receiver of information.

Most parameters can be a source of data for a link, except parameter values that
contain an integer representing an ENUM (text choice). These are not allowed, since
the integer is not actual data (it represents a value). Table B.6 lists the parameters that
can be destinations. All links must be established between equal data types
(parameter value formatted in floating point can only source data to a destination
parameter value that is also floating point).

Removing/Installing the HIM

The HIM can be removed or installed while the drive is powered.

Important: HIM removal is only permissible in Auto mode. If the HIM is removed while

in Manual mode or the HIM is the only remaining control device, a fault
will occur

Step

Key(s)

Example Displays

To remove the HIM . . .

1.

Press ALT and then Enter
(Remove). The Remove HIM
confirmation screen appears.

2.

Press Enter to confirm that you
want to remove the HIM.

3.

Remove the HIM from the drive.

To install HIM . . .

1.

Insert into drive or connect cable.

ALT

+

Remove Op Intrfc:
Press Enter to
Disconnect Op Intrfc?
(Port 1 Control)