226 fault bus volts, 227 status 1 @ fault, 228 status 2 @ fault – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 91

Advertising
background image

Parameter Descriptions

3-65

Captures and displays the DC bus voltage of the drive at the time of the last fault.

Captures and displays Drive Status 1 bit pattern at the time of the last fault.

Captures and displays Drive Status 2 bit pattern at the time of last fault.

226

Fault Bus Volts

Range:

0.0 to Max Bus Volts [0.1 VDC]

Default:

Read Only

Access:

2

Path: Utility>Diagnostics

See also:

224-230

227

Status 1 @ Fault

Range:

See figure 3.20

Default:

Read Only

Access:

2

Path: Utility>Diagnostics

See also:

209, 224-230

Figure 3.20 – Status 1 @ Fault (227)

0

1

1

0

0

0

0

1

0

1

1

1

0

0

0

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Condition True
0 =Condition False
x =Reserved

Bit #

Ready

Activ

e

Command Dir

Actual Dir

Acceler

ating

Deceler

ating

Alar

m

Faulted

At Speed

Local ID 0

Local ID 1

Local ID 2

Spd Ref ID 0

Spd Ref ID 1

Spd Ref ID 2

Spd Ref ID 3

Nibble 1

Nibble 2

Nibble 3

Nibble 4

228

Status 2 @ Fault

Range:

See figure 3.21

Default:

Read Only

Access:

2

Path: Utility>Diagnostics

See also:

210, 224-230

Figure 3.21 – Status 2 @ Fault (228)

0

0

0

0

0

0

0

0

0

0

0

0

0

0

x

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Condition True
0 =Condition False
x =Reserved

Bit #

Read

y

Active

Running

Jog

ging

Stopping

DC Braking

A

utoT

uning

DB Active

A

utoRst Ctdn

A

utoRst Act

Curr Limit

Bus Freq Reg

Motor Overld

DPI at 500 k

Reser

ved

PTC HW