3-98

DBT Reach Drive User Manual

46 = Run w/Comm: Allows the comm start bit to operate like a run with the run input
on the terminal block. Ownership rules apply.

47 = Hold Step: Inhibits profile from transitioning to next step when active.

48 = Set Home: The input establishes the “home” position in speed profiling.

49 = Find Home: Starts the commissioning procedure when a start command is
issued to automatically position the motor to a home position established by a limit
switch.

50 = Home Limit: This input is used for the “home” position.

51 = Vel Override: When active, multiplies value of Step X Velocity by % value in Vel
Override.

52-56 = Pos Sel 1-5: The binary value of these inputs is used to select the starting
step number for the profile.

57 = Prof Input: (Profile Input) Must be chosen if Step X Type is set to Dig Input and
the digital input value that is entered in Step X Value is the value of this digital input
selector.

Type 2 Alarms

Some digital input programming may cause conflicts that result in a Type 2 alarm. For
example, Digital In1 Sel set to 5 (Start) in 3-wire control, and Digital In2 Sel set to 7
(Run) in 2-wire control.

Sets the analog output value from a communication device.

Example: Set Data ln Ax (300-201) to 377 (value from communication device). Then
set Analog Outx Sel (342, 345) to 24 = Param Cntl.

377
378

Anlg1 Out Setpt
Anlg2 Out Setpt

Range:

0.000 to 20.000 mA or -/+10.000 V [0.001 mA or 0.001 V]

Default:

20.000 mA or 10.000 V

Access:

2

Path: Inputs & Outputs>Analog Outputs

See also: