Example:
Mask OR: If any bits in the value are set in the mask, then the output is On.
Mask AND: If all bits in the value are set in the mask, then the output is On.
Selects the encoder type - single channel or quadrature. Options 1 and 3 detect a
loss of encoder signal (when using differential inputs) regardless of the Feedback
Select (80) setting.
For FVC Vector mode, use a quadrature encoder only (option 0 or 1).
If a single channel encoder is used (option 2 or 3) in sensorless vector or V/Hz mode,
select 2 = Reverse Dis in Direction Mode (190).
Figure 3.37 – Dig Out Mask
Selected Value
0
0
0
0
1
1
0
0
1
1
1
1
0
0
0
0
Mask
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
Result
Output On
Selected Value
0
0
0
0
1
1
0
0
1
1
1
1
0
0
0
0
Mask
0
0
0
0
0
0
0
0
1
0
0
0
0
1
0
0
Result
Output Off
0
0
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Output Energized
0 =Output De-energized
x =Reserved
Bit #
Net DigOut1
Net DigOut2
Net DigOut3
412
Motor Fdbk Type
Range:
0 = Quadrature
1 = Quad Check
2 = Single Chan
3 = Single Check
Default:
0 = Quadrature
Access:
0
Path: Motor Control>Speed Feedback
See also: