2.5.3 Signal and Control Wire Types

Table 2.5 – Recommended Signal Wire

Signal Type/
Where Used

Belden Wire Type(s)

(or equivalent)

Description

Minimum

Insulation

Rating

Analog I/O
and PTC

8760/9460

0.750 mm

2

(18AWG),

twisted pair, 100% shield

with drain

1

.

1.

If the wires are short and contained within a cabinet which has no sensitive circuits, the use of shielded

wire may not be necessary, but is always recommended.

300V,
75-90
degrees C
(167-194
degrees F)

8770

0.750 mm

2

(18AWG), 3

cond., shielded for remote
pot only.

Encoder/
Pulse I/O
<30 m (100
ft.)

Combined:

9730

2

2.

9730 is 3 individually shielded pairs (2 channel + power). If 3 channel is required, use 9728.

0.196 mm

2

(24AWG),

individually shielded.

Encoder/
Pulse I/O
30 to 152 m
(100 to 500
ft.)

Signal:

9730/9728

2

0.196 mm

2

(24AWG),

individually shielded.

Power:

8790

3

3.

8790 is 1 shielded pair.

0.750 mm

2

(18 AWG)

Combined:

9892

4

4.

9892 is 3 individually shielded pairs (3 channel), 0.33

2

(22 AWG) + 1 shielded pair 0.5 mm

2

(20 AWG)

for power.

0.330 mm

2

or 0.500 mm

2

4

Encoder/
Pulse I/O
152 to 259 m
(500 to 850
ft.)

Signal:

9730/9728

2

0.196 mm

2

(24AWG),

individually shielded.

Power:

8790

3

0.750 mm

2

(18 AWG)

Combined:

9773/9774

5

5.

9773 is 3 individually shielded pairs (2 channel + power). If channel 3 is required, use 9774.

0.750 mm

2

(18 AWG) or

0.500 mm

2

, individually

shielded pair