600 torqprove cnfg – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 142

Advertising
background image

3-116

DBT Reach Drive User Manual

Value of the signal being sent out of the Universal Scale Block. Typically this value is
used as the source of information and will be linked to another parameter.

Parameters 500 - 598 are found in the Advanced Tuning
Parameters Section (Section 11.2).

Enables/disables torque/brake proving feature. When Enabled, Digital Out1 Sel (380)
becomes the brake control.

This value is not changed when parameters are reset to factory defaults.

Enable = Enables Torque Proving features.

Encoderless = Enables encoderless operation - bit 0 must also be enabled.

MicroPosSel = A “1” allows the Micro Position digital input to change the speed
command while the drive is running.

Preload Sel = “0” uses the last torque for preload. “1” uses “TorqRef A” if commanded
direction is forward and “TorqRef B” for reverse.

481
487
493
499

Scale1 Out Value
Scale2 Out Value
Scale3 Out Value
Scale4 Out Value

Range:

-/+ 32767.000 [0.001]

Default:

Read Only

Access:

2

Path: Utility>Scaled Blocks

See also:

600

TorqProve Cnfg

Range:

See figure 3.39

Default:

See figure 3.39

Access:

2

Path: Applications>Torque Proving

See also:

Figure 3.39 – TorqProve Cnfg

0

0

0

0

0

0

x

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Enabled
0 =Disabled
x =Reserved

Bit #

Factory Default Bit Values

Enab

le

Encoderless

Micr

oP

osSel

Preload Sel

Load Spd Lim

NoEnc

lsBkSlp

Parameters Section (Section 3.2).