705 profile command, 707 encoder pos tol, 708 counts per unit – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 156

Advertising
background image

3-130

DBT Reach Drive User Manual

Control word for the profile/indexer. The control functions are the same as those in the
digital input section. If a digital input is configured to provide the starting step (bits
0-4), then its starting step value takes priority over Profile Command. If a digital input
is configured for any of bits 8-12, the corresponding functions will respond to the
digital input status or the status of Profile Command.

Sets the “At Position” tolerance window (See Profile Status (700) bit 12) around the
encoder count. The value is subtracted from and added to the encoder unit value. It is
applied to all steps using encoder units.

Sets the number of encoder counts equal to one unit. A 1024 RPM quadrature
encoder has 4096 pulses in one revolution.

705

Profile Command

Range:

See figure 3.43

Default:

See figure 3.43

Access:

2

Path: Pos/Spd Profile>ProfSetup/Status

See also:

Figure 3.43 – Profile Command

0

0

0

0

0

x

x

x

0

0

0

0

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Enabled
0 =Disabled
x =Reserved

Bit #

Factory Default Bit Values

Star

t Step 1

Star

t Step 2

Star

t Step 3

Star

t Step 4

Star

t Step 5

Hold Step

Pos Redefine

Find Home

Vel Override

707

Encoder Pos Tol

Range:

1 to 50000 [1]

Default:

10

Access:

2

Path: Pos/Spd Profile>ProfSetup/Status

See also:

708

Counts per Unit

Range:

1 to 1000000 [1]

Default:

4096

Access:

2

Path: Pos/Spd Profile>ProfSetup/Status

See also: