4-14

DBT Reach Drive User Manual

Software
Fault

89

Microprocessor handshake
error.

Replace Main Control Board.

SW
OverCurrent

36

The drive output current has
exceeded the software
current.

Check for excess load,
improper DC boost setting. DC
brake volts set too high.

TorqProv Spd
Band

20

Difference between
Commanded Speed and
Encoder Speed has exceeded
the level set in Spd Dev Band
for a time period greater than
Spd Band Integrat.

1.

Check wiring between drive
and motor.

2.

Check release of
mechanical brake.

Trnsistr
OvrTemp

9

Output transistors have
exceeded their maximum
operating temperature.

Check for proper temperature
and flow rate of coolant.

UnderVoltage

4

DC bus voltage fell below the
minimum value of 407V DC at
400/480V input or 204V DC at
200/240V input.

Enable/disable with Fault
Config 1(233).

Monitor the incoming AC line
for low voltage or power
interruption.

UserSet1
Chksum

101

The checksum read from the
user set does not match the
checksum calculated.

Re-save user set.

UserSet2
Chksum

102

UserSet3
Chksum

103

Table 4.6 – Fault Names Cross-Referenced by Fault Number

No.

1

Fault

No.

1

Fault

No

1

Fault

2

Auxiliary Input

29

Analog In Loss

87

IXo VoltageRange

3

Power Loss

39

Phase V to Grnd

88

Software Fault

4

UnderVoltage

40

Phase W to Grnd

89

Software Fault

5

OverVoltage

41

Phase UV Short

90

Encoder Quad Err

7

Motor Overload

42

Phase VW Short

91

Encoder Loss

8

Heatsink OvrTemp

43

Phase UW Short

92

Pulse ln Loss

9

Trnsistr OvrTemp

48

Params Defaulted

93

Hardware Fault

12

HW OverCurrent

49

Drive PowerUp

100 Parameter Chksum

13

Ground Fault

51

Flt QueueCleared

101-

103

UserSetX Chksum

15

Load Loss

52

Faults Cleared

104 Pwr Brd Chksum1

16

Motor Thermistor

55

Cntl Bd OverLoad

105 Pwr Brd Chksum2

17

Input Phase Loss

63

Shear Pin

106 Incompat MCB-PB

18

Hardware PTC

64

Drive OverLoad

107 Replaced MCB-PB

20

TorqProv Spd Band

69

DB Resistance

108 Anlg Cal Chksum

21

Output Phase Loss

70

Power Unit

120 I/O Mismatch

24

Decel Inhibit

71- 75 Port 1-5 Net Loss

121 I/O Comm Loss

25

OverSpeed Limit

77

IR Volts Range

122 I/O Failure

28

See Manual

78

FluxAmpsRef Rang

130 Hardware Fault

Table 4.5 – Fault Descriptions and Corrective Actions (Continued)

Fault

No.

Ty

p

e

Description

Action