449 speed desired bw, 450 total inertia, 451 speed loop meter – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 138: 454 rev speed limit

Advertising
background image

3-112

DBT Reach Drive User Manual

Sets the speed loop bandwidth and determines the dynamic behavior of the speed
loop. As bandwidth increases, the speed loop becomes more responsive and can
track a faster changing speed reference.

Adjusting this parameter will cause the drive to calculate and change Ki Speed Loop
(445) and Kp Speed Loop (447) gains.

Represents the time in seconds for a motor coupled to a load to accelerate from zero
to base speed at rated motor torque. The drive calculates Total Inertia during the
autotune inertia procedure.

Adjusting this parameter will cause the drive to calculate and change Ki Speed Loop
(445) and Kp Speed Loop (447) gains.

Value of the speed regulator output.

Sets a limit on speed in the negative direction, when in FVC Vector mode. Used in
bipolar mode only. A value of zero disables this parameter and uses Maximum Speed
for reverse speed limit.

449

Speed Desired BW

Range:

0.0 to 250.0 Radian/sec [0.1 Radian/sec]

Default:

0.0 Radians/sec

Access:

2

Path: Speed Command>Speed Regulator

See also:

53

FV

450

Total Inertia

Range:

0.01 to 600.0 sec [0.01 sec]

Default:

0.10 secs

Access:

2

Path: Speed Command>Speed Regulator

See also:

53

FV

451

Speed Loop Meter

Range:

-/+ 800.0% /Hz/RPM [0.1%/Hz/RPM]

Default:

Read Only

Access:

2

Path: Speed Command>Speed Regulator

See also:

53, 79, 121

FV

454

Rev Speed Limit

Range:

-Max Speed to 0.0 Hz or -Max Speed to 0.0 RPM [0.0 Hz or 0.0 RPM]

Default:

0.0 RPM

Access:

1

Path: Speed Command>Speed Mode & Limits

See also:

FV