646 total gear ratio, 647 db resistor, 648 gearbox limit – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 150: 650 adj volt phase

Advertising
background image

3-124

DBT Reach Drive User Manual

Displays the calculated total gear ratio as follows:

[(Gearbox Sheave) x (Gearbox Ratio)]/[Motor Sheave]

Calculates the negative torque maximum available from the dynamic brake resistor.

Sets the gearbox torque limit. This value is used in determining the Pos Torque Limit
(436) and Neg Torque Limit (437).

Selects the type voltage.

0 = 1 Phase: Operates single phase loads connected to the U and V phases. Not
designed to operate single phase motors.

1 = 3 Phase: Operates three phase loads.

646

Total Gear Ratio

Range:

0.00 to 32000.00 [0.01]

Default:

Read Only

Access:

2

Path: Applications>Oil Well Pump

See also:

647

DB Resistor

Range:

0.0 to 100.0 Ohms [0.1]

Default:

10.4

Access:

2

Path: Applications>Oil Well Pump

See also:

648

Gearbox Limit

Range:

0.0 to 200.0% [0.1%]

Default:

100.0 %

Access:

2

Path: Applications>Oil Well Pump

See also:

650

Adj Volt Phase

Range:

0 = 1 Phase
1 = 3 Phase

Default:

1 = 3 Phase

Access:

2

Path: Applications>Adjust Voltage

See also:

Advertising