94 speed ref b hi, 95 speed ref b lo, 96 tb man ref sel – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 50: 97 tb man ref hi

Advertising
background image

3-24

DBT Reach Drive User Manual

Scales the upper value of the Speed Ref B Sel (93) selection when the source is an
analog input.

Scales the lower value of the Speed Ref B Sel (93) selection when the source is an
analog input.

Specifies the manual speed reference source when a digital input is configured for
auto/manual.

Important: Analog ln 2 is not a valid selection if it was selected for Trim ln Select

(117), PI Feedback Sel (128), PI Reference Sel (126), Current Lmt Sel
(147) or Sleep Wake Ref (179).

Scales the upper value of the TB Man Ref Sel selection when the source is an analog
input.

94

Speed Ref B Hi

Range:

-/+Maximum Speed [0.1 Hz or 0.01 RPM]

Default:

Maximum Speed

Access:

1

Path: Speed Command>Speed References

See also:

79, 93, 190

95

Speed Ref B Lo

Range:

-/+Maximum Speed [0.1 Hz or 0.01 RPM]

Default:

0.0

Access:

1

Path: Speed Command>Speed References

See also: 79, 90, 93, 190

96

TB Man Ref Sel

Range:

1 = Analog In 1
2 = Analog In 2
3-8 = Reserved
9 = MOP Level

Default:

2 = Analog In 2

Access:

1

Path: Speed Command>Speed References

See also:

97, 98

97

TB Man Ref Hi

Range:

-/+Maximum Speed [0.1 Hz or 0.01 RPM]

Default:

Maximum Speed

Access:

1

Path: Speed Command>Speed References

See also: 79, 96

Advertising