217 dig out status, 218 drive temp, 219 drive ol count – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 89

Advertising
background image

Parameter Descriptions

3-63

Current state of the digital outputs.

Present operating temperature of the drive power section.

Accumulated percentage of drive overload. Continuously operating the drive over
100% of its rating will increase this value to 100% and cause a drive fault.

217

Dig Out Status

Range:

See figure 3.19

Default:

Read Only

Access:

2

Path: Utility>Diagnostics
Inputs & Outputs>Digital Outputs

See also:

380-384

Figure 3.19 – Dig Out Status (276)

0

0

x

0

x

x

x

x

x

x

x

x

x

x

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Output Energized
0 =Output De-energized
x =Reserved

Bit #

Digital Out1

Digital Out2

Digital Out3

218

Drive Temp

Range:

0 to 100.0 degC [0.1 degC]

Default:

Read Only

Access:

2

Path: Utility>Diagnostics

See also:

219

Drive OL Count

Range:

0.0 to 100.0% [0.1%]

Default:

Read Only

Access:

2

Path: Utility>Diagnostics

See also:

150

Advertising