Parameter Descriptions

3-89

Sets the analog output value when the source value is at maximum.

Sets the analog output value when the source value is at minimum.

Sets the high value for the range of analog out scale.

Entering 0.0 will disable this scale and max scale will be used.

Example: If Analog Outx Sel (342,345) = Commanded Trq, then a value of 150 =
150% scale in place of the default 800%.

343
346

Analog Out1 Hi
Analog Out2 Hi

Range:

0.000 to 20.000 mA or -/+10.000 V [0.001 mA or 0.001 V]

Default:

20.000 mA or 10.000 V

Access:

1

Path: Inputs & Outputs>Analog Outputs

See also:

340, 342

344
347

Analog Out1 Lo
Analog Out2 Lo

Range:

0.000 to 20.000 mA or -/+10.000 V [0.001 mA or 0.001 V]

Default:

0.000 mA or 0.000 V

Access:

1

Path: Inputs & Outputs>Analog Outputs

See also: 340, 342

354
355

Analog Out1 Scale
Analog Out2 Scale

Range:

Analog Out1Sel [0.01]

Default:

0.0 (Disable)

Access:

2

Path: Inputs & Outputs>Analog Outputs

See also: 340, 342