Appendix D-20

DBT Reach Drive User Manual

Ramp to
Stop

This method uses drive output reduction to stop the load.

1.

On Stop, drive output will decrease according to the
programmed pattern from its present value to zero. The pattern
may be linear or squared. The output will decrease to zero at the
rate determined by the programmed Maximum Freq (55) and the
programmed active Decel Time x.

2.

The reduction in output can be limited by other drive factors such
as such as bus or current regulation.

3.

When the output reaches zero the output is shut off.

4.

The motor, if rotating, will coast from its present speed for a time
that is dependent on the mechanics of the system (inertia,
friction, etc).

Mode

Description

DC Hold Time

DC

Hold

Level

Stop

Command

Time

Output Voltage

Output Current

Motor Speed

Output Voltage

Output Current

Zero

Command

Speed