430 torq ref a div, 434 torq ref b mult, 435 torque setpoint1 – Rockwell Automation Liqui-Flo DBT Reach Drive User Manual

Page 135: 436 pos torque limit

Advertising
background image

Parameter Descriptions

3-109

Defines the value of the divisor for the Torque Ref A Sel (427) selection.

Defines the value of the multiplier for the Torque Ref B Sel (431) selection.

Provides an internal fixed value for Torque Setpoint when Torque Ref Sel is set to
Torque Setpt.

Defines the torque limit for the positive torque reference value. The reference will not
be allowed to exceed this value.

430

Torq Ref A Div

Range:

0.1 to 3276.7 [0.1]

Default:

1.0

Access:

1

Path: Motor Control>Torq Attributes

See also:

53

FV

434

Torq Ref B Mult

Range:

-/+ 3276.7 [0.1]

Default:

1.0

Access:

1

Path: Motor Control>Torq Attributes

See also:

53

FV

435

Torque Setpoint1

Range:

-/+ 800.0% [0.0%]

Default:

0.0%

Access:

1

Path: Motor Control>Torq Attributes

See also:

53

FV

436

Pos Torque Limit

Range:

0.0 to 800.0% [0.1%]

Default:

200.0%

Access:

1

Path: Motor Control>Torq Attributes

See also:

53

FV