716

For more information, see "

Selecting devices by IP address

", "

Selecting devices by custom view

",

or "

Selecting devices by network segment

."

You can also select devices by using the Select button located to the right of the Device IP field. This
enables you to use IMC display and search capabilities to select the device(s) from established

groups and views either By View or by query using the Advanced feature. See "

Adding devices by

View

" and "

Adding devices by Advanced query

."

7.

Modify which error conditions trigger mail notifications from the Concerned Alarms list. Operators
can select all conditions or only a specified subset of conditions that trigger alarms.

All Alarms: With this option, all alarms configured in IMC trigger an email notification to be sent if
the alarm condition is triggered.

Selected Alarms: With this option, only the alarms you select in alarm notification generate an

email notification if the alarm condition is triggered. Further, if you choose Selected Alarms, you
can select which alarm conditions generate email alarm notifications.

8.

To configure which conditions to send notifications for:

a.

Click Select located to the right of the Concerned Alarms field. The Select Alarm dialog box
appears.

b.

In the Select Alarm dialog box, locate the Enterprise MIB that contains an object or condition
that you want to alarm on.

9.

To expand your view of the MIB, click the arrow key next to the MIB that contains an object or
condition that you want to alarm on, or click the Expand all icon located in the upper right

corner of the Select Alarm dialog box to expand your view to display all MIB.

10.

You can also use the query function located at the top of the Select Alarm dialog box to locate the
object that you want alarm on by entering one or more of the following search criteria:

{

Trap Name: Enter the object name for the trap you want to locate in the Trap Name field.

{

Trap OID: Enter the Object ID for the trap in the Trap OID field.

{

Severity: Select a severity for the trap.

{

Enterprise Name: Enter a partial or complete name for the Enterprise MIB you want to locate in
the Enterprise Name field.

{

Enterprise OID: Enter a partial or complete Enterprise ID for the MIB you want to locate in the
Enterprise OID field.

11.

Do one of the following:

{

Click Query to submit your search criteria. The results of your query display in the dialog box.

{

Click Reset to clear your query criteria and to restore the full list of MIBs and traps.

12.

Enable or disable the Automatically select recovered alarms function. Options are:

{

Open—Enable the Automatically select recovered alarms function. When the selected traps
have recovered alarms defined, IMC automatically selects the recovered alarms for the selected

traps.

{

Close—Disable the Automatically select recovered alarms function. When the selected traps
have recovered alarms defined, IMC does not automatically select the recovered alarms for the
selected traps.

13.

Click the checkbox to select a MIB object that you want to add to this alarm rule.

14.

Scroll down to the bottom of the MIB list and click OK.
It may take a while for the Select Alarm dialog box to close. When the box closes, it updates the
Concerned Alarms field with the configured object or alarm condition.