8.7 AT^SMOND

s

AC75_ATC_V01.002

Page 206 of 569

10/30/06

Confidential / Released

8.7

AT^SMOND Cell Monitoring

The

AT^SMOND

execute command can be used to obtain status information of the service cell and up to six neigh-

bour cells. The advantage over other cell monitoring commands is that

AT^SMOND

delivers more detailed infor-

mation about the received signal strength.

Syntax

Parameter Description

Serving cell information (comma-separated, no cr/lf included)

<MCC>

,

<MNC>

,

<LAC>

,

<cell>

,

<BSIC>

,

<chann>

,

<RxLev>

,

<RxLev>

Full,

<RxLev>

Sub,

<RxQual>

,

<RxQual

>

Full,

<RxQual>

Sub,

<Timeslot>

If no serving cell is found, unavailable values are omitted:" ,,,,,,

<RxLev>

,,,0,,,0"

Neighbour cell information for neighbour cell 1 through 6 (comma-separated, no cr/lf included)

<MCC>

1

,

<MNC>

1

,

<LAC>

1

,

<cell>

1

,

<BSIC>

1

,

<chann>

1

,

<RxLev>

1

, (these parameters repeated for neighbour

cells 2 through 6 with no CR/LF): ...

<MCC>

6

,

<MNC>

6

,

<LAC>

6

,

<cell>

6

,

<BSIC>

6

,

<chann>

6

,

<RxLev>

6

An unavailable cell appears as follows: " ,,,,,,0"

Values for RSSI and BER (comma-separated, no cr/lf included)

<RSSI>

,

<BER>

Mobile country code
3 digits, e.g. 232
000

Not decoded

Test Command

AT^SMOND=?

Response(s)

OK

ERROR

+CME ERROR

Exec Command

AT^SMOND

Response(s)

^SMOND:

[

<sci>

][,

<nci>

][,

<TA>

][,

<rssiber>

]

OK

ERROR

+CME ERROR

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS, 3GPP TS 05.08

+

+

+

+

+

+

+

-

-

-

<sci>

(str)

<nci>

(str)

<rssiber>

(str)

<MCC>

(num)