AC75 AT Command Set

2.14 AT^SCFG

s

AC75_ATC_V01.002

Page 74 of 569

10/30/06

Confidential / Released

URC RING line Active Time
This parameter can be used to control how long the RING line is activated to indicate URCs (both for idle inter-

faces and, if configured by the parameter "URC/Datamode/Ringline" (

<udri>

), if link is reserved) and, if con-

figured by the parameter "GPRS/RingOnIncomingData", to indicate incoming GPRS IP data packets

(

<groid>

).

Parameter is global for all interfaces, volatile and will not be reset by

AT&F

.

“0“

RING line will be activated for a time between 4.6 and 9.2 ms.

“1“

RING line will be activated for about 100ms.

“2“

(P)

RING line will be activated for about 1s.

Userware Autostart
Specifies if the userware is started automatically on power-up.

If autostart is enabled, it is no longer possible to use the multiplexer (see

AT+CMUX

).

If the Java application starts, all current calls will be terminated.

The Userware/Autostart mechanism takes effect also in Airplane modeand CHARGE-ONLY-MODE.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

.

“0“

(D)

Userware autostart disabled

“1“

Userware autostart enabled

Userware Autostart AppName
Specifies the absolute path of the userware (the jar/jad file containing the desired application) to be started auto-

matically on power-up. The local flash file system is identified by: "A:", directory separator is "/" (002Fh). The

underline character "_" (005Fh) will not be supported.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

.

Parameter length: maximum 100 characters.

Userware Autostart Delay
0

(D)

...10000

Specifies the delay time (in 100ms) when the userware is started automatically

after power-up.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

.

Userware Password
Password used to change values of userware parameters.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

.

The maximum length of a given password is 8 characters. It is allowed to have an empty password (this is the

value on delivery of the module).

CAUTION: Be careful not to lose the password. There is no way to reset or recover a forgotten password or to

obtain a new password from the manufacturer.

Userware Debug Interface Local IP address
Local IP address of the module used by the userware debugger.

Parameter is global, volatile and not reset by

AT&F

.

<urat>

(str)(+CSCS)

<ua>

(str)(+CSCS)

<uaa>

(str)(+CSCS)

<uad>

(str)(+CSCS)

<upwd>

(str)(+CSCS)

<udbgif1>

(str)(+CSCS)