AC75 AT Command Set

10.1 AT^SICS

s

AC75_ATC_V01.002

Page 257 of 569

10/30/06

Confidential / Released

Parameter Description

0...5

Internet connection profile identifier.

The

<conProfileId>

identifies all parameters of a connection profile, and,

when a service profile is created with

AT^SISS

the

<conProfileId>

needs

to be set as "conId" value of the

AT^SISS

parameter

<srvParmTag>

.

Internet connection parameter.
“conType“

Type of Internet connection.

For supported values of

<conParmValue>

refer to

<conParmValue-con-

Type>

.

“alphabet“

Selects the character set for input and output of string parameters within a pro-

file.

The selected value is bound to the specific profile. This means that different

profiles may use different alphabets. Unlike other parameters the alphabet can

be changed no matter whether the

<conParmTag>

value "conType" has been

set.

For supported values of

<conParmValue>

refer to

<conParmValue-

alphabet>

.

“user“

User name string: maximum 32 characters (where "" is default).

“passwd“

Password string: maximum 32 characters (where ***** is default).

If

<conParmValue-authMode>

is "MsChapV1" then the maximum password

length is 16 characters.

“apn“

Access point name string value: maximum 100 characters (where "" is default).

“inactTO“

Inactivity timeout value in seconds: 0 ... 2

16

-1, default = 20

Number of seconds the bearer remains open although the service no longer

needs the bearer connection.

Do not set the timeout value below 3 sec. This may result in problems when

using the

<eodFlag>

(set in the last

AT^SISW

command to terminate an

upload data stream).

The value -1 indicates that, after opening the bearer with

AT^SICO

, the inac-

tivity timeout is currently disabled. Closing the bearer with

AT^SICC

restores

the previously set "inactTO" value of the concerned connection profile.

“calledNum“

Called BCD number.

“dataRate“

Data rate.

For supported values of

<conParmValue>

refer to

<conParmValue-dat-

aRate>

.

“dataType“

Data call type.

For supported values of

<conParmValue>

refer to

<conParmValue-

dataType>

.

Write Command

AT^SICS=

<conProfileId>

,

<conParmTag>

,

<conParmValue>

Response(s)

OK

ERROR

+CME ERROR:

<err>

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

-

+

+

+

+

+

+

-

+

-

<conProfileId>

(num)

<conParmTag>

(str)