At^smgo, Ac75 at command set – Siemens AC75 User Manual

Page 396

Advertising
background image

AC75 AT Command Set

13.24 AT^SMGO

s

AC75_ATC_V01.002

Page 396 of 569

10/30/06

Confidential / Released

13.24

AT^SMGO Set or query SMS overflow presentation mode or
query SMS overflow

The write command sets the overflow presentation mode.

The read command returns the overflow presentation mode and the SMS overflow status.

Syntax

Unsolicited Result Code

SMS buffer change:

^SMGO:

<mode>

Status of SMS buffer has changed.

Parameter Description

SMS overflow presentation mode
[0]

(&F)

Disable

1

Enable

SMS overflow status
0

Space available

1

SMS buffer full (The buffer for received short messages is

<mem3>

. See

AT+CPMS

.)

2

Buffer full and new message waiting in SC for delivery to phone

Test Command

AT^SMGO=?

Response(s)

^SMGO:

(list of supported

<n>

s)

OK

Read Command

AT^SMGO?

Response(s)

^SMGO:

<n>

,

<mode>

OK

ERROR

+CMS ERROR

Write Command

AT^SMGO=

<n>

Response(s)

OK

ERROR

CME ERROR

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS

+

+

+

+

+

+

+

-

+

-

<n>

(num)(&W)(&V)

<mode>

(num)(&V)