Langid, Vendorid, Productid – Siemens AC75 User Manual

Page 72: Manufacturer, Product, Serialno, Ac75 at command set

Advertising
background image

AC75 AT Command Set

2.14 AT^SCFG

s

AC75_ATC_V01.002

Page 72 of 569

10/30/06

Confidential / Released

Language ID
Please refer to USB.ORG

[28]

to find the language IDs currently defined for USB devices. If parameter

<langId>

is not specified, the default value of the Siemens standard USB Device Descriptor configuration

applies (US English).

Parameter is global, stored non-volatile in ME and not reset by

AT&F

. Setting will be active after AC75 restart.

Parameter length: maximum 4 characters.

Vendor ID
This parameter represents the Vendor ID obtained from the USB Implementers Forum. The Vendor ID will,

together with the Product ID, be transmitted to the host during initialization. The given Vendor ID must be

included in the INF file needed for Windows.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

. Setting will be active after AC75 restart.

Parameter length: maximum 4 characters.

Product ID
Product ID (PID) defined by the application manufacturer to identify the USB device.

The Product ID will, together with the Vendor ID, be transmitted to the host during initialization. The given Prod-

uct ID must be included in the INF file needed for Windows.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

. Setting will be active after AC75 restart.

Parameter length: maximum 4 characters.

Manufacturer name
Optional manufacturer string defined by the application manufacturer. If specified with

<manufacturer>

the

same string shall be included in the INF file needed for Windows.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

. Setting will be active after AC75 restart.

Parameter length: maximum 63 characters.

Product string
Optional product name defined by the application manufacturer. If specified with

<product>

it is recommended

to include the same string into the INF file.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

. Setting will be active after AC75 restart.

Parameter length: maximum 63 characters.

Device's serial number
Optional serial number. Empty string if not used, like in the case of the Siemens standard USB Device Descriptor

configuration.

A serial number has several advantages. For example, it enables the host to assign the same virtual COM port

to same USB device even though the device is connected to another USB port. This eliminates the need for the

host to load the driver again.

Parameter is global, stored non-volatile in ME and not reset by

AT&F

. Setting will be active after AC75 restart.

If parameter

<serialNo>

is not specified, the default value of Siemens standard USB Device Descriptor

applies.

Parameter length: maximum 63 characters.

<langId>

(str)(+CSCS)

<vendorId>

(str)(+CSCS)

<productId>

(str)(+CSCS)

<manufacturer>

(str)(+CSCS)

<product>

(str)(+CSCS)

<serialNo>

(str)(+CSCS)

Advertising