Ac75 at command set – Siemens AC75 User Manual

Page 490

Advertising
background image

AC75 AT Command Set

19.6 AT^SCTM

s

AC75_ATC_V01.002

Page 490 of 569

10/30/06

Confidential / Released

19.6

AT^SCTM Set critical operating temperature presentation mode
or query temperature

Use this command to monitor the temperature range of the module and the battery. The write command enables

or disables the presentation of URCs to report critical temperature limits.

CAUTION: During a guard period of two minutes after power-up, the module will not switch off, even if the critical

temperature limit is exceeded. This allows the user to issue emergency calls before the module switches off.

During this guard period, the module operates in an automatic report mode: URCs can be always displayed

regardless of the selected mode

<n>

. Refer to Section

19.6.1

,

Deferred shutdown

for detail.

Syntax

Unsolicited Result Codes

URC 1

URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level, or when

it is back to normal.

^SCTM_A:

<m>

for battery temperature

URC 2

^SCTM_B:

<m>

for module (board) temperature

Test Command

AT^SCTM=?

Response(s)

^SCTM:

(list of supported

<n>

s)[, (range of

<temp>

in Celsius)]

OK

Read Command

AT^SCTM?

Response(s)

^SCTM:

<n>

,

<m>

[,

<temp>

]

OK

ERROR

+CME ERROR

Write Command

AT^SCTM=

<n>

[,

<p>

]

Response(s)

OK

ERROR

+CME ERROR

Reference(s)

PIN