At^snfd, Ac75 at command set – Siemens AC75 User Manual

Page 466

Advertising
background image

AC75 AT Command Set

18.10 AT^SNFD

s

AC75_ATC_V01.002

Page 466 of 569

10/30/06

Confidential / Released

18.10

AT^SNFD Set audio parameters to manufacturer default values

AT^SNFD

sets the active audio parameters to manufacturer defined default values. These default values can be

changed and stored by the user and also by download with a new set of parameters.

The restored values are:

AT^SNFA

:

<atten>

AT^SNFI

:

<inBbcGain>

,

<inCalibrate>

AT^SNFO

:

<outBbcGain>

,

<outCalibrate>

[0 to 4],

<sideTone>

AT^SAIC

:

<io>

,

<mic>

,

<ep>

AT^SNFS

:

<audMode>

Syntax

Note

• Remember that the factory set audio mode 1 is fixed to

<outStep>

=4. Consequently,

AT^SNFD

restores

<audMode>

together with

<outStep>

=4, but does not affect the values of

<outStep>

currently selected in

audio modes 2 - 6. This means, if

<audMode>

=1, the read commands

AT^SNFO

,

AT^SNFV

and

AT+CLVL

will

always deliver

<outStep>

=4. In all other modes the

<outStep>

value is retained until explicitly changed.

Test Command

AT^SNFD=?

Response(s)

OK

Exec Command

AT^SNFD

Response(s)

OK

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

SIEMENS

-

+

+

+

+

+

+

-

+

-